Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Circ Arrhythm Electrophysiol ; 15(1): e010516, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34962134

RESUMO

BACKGROUND: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. METHODS: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. RESULTS: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. CONCLUSIONS: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Doença Iatrogênica , Traumatismos dos Nervos Periféricos/epidemiologia , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/diagnóstico , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Int J Cardiol Heart Vasc ; 37: 100893, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34712772

RESUMO

BACKGROUND: Data reporting a head-to-head comparison between Amulet and Watchman devices are scarce. The aim of this study was to compare the Watchman™ versus Amulet™ left atrial appendage closure (LAAC) devices in a consecutive, industry-independent registry. METHODS: Patients who underwent LAAC using Watchman or Amulet devices from January 2014 to December 2019 at the University Heart Center Lübeck, Lübeck, Germany were included in the present analysis. Primary endpoints included periprocedural complications (in-hospital death, pericardial tamponade, device embolization, stroke, major bleeding and vascular access complications), and complications during long-term follow-up (ischemic stroke, hemorrhagic stroke, thromboembolism, device thrombus, bleeding and death). RESULTS: After matching the patients for age (±5 years), gender, CHA2DS2Vasc score (±1) and HASBLED score (±1), each of the Watchman and the Amulet groups included 113 patients. Patients in the Amulet group had significantly more periprocedural complications (2.7% vs 10.6%, p = 0.029; respectively) and more major bleeding complications (0% vs 5.3%, p = 0.029; respectively). During long-term follow-up, the rate of events was comparable between the Watchman and Amulet groups (18.3% versus 20.8%, p = 0.729; respectively). CONCLUSION: Amulet LAAC device was associated with increased periprocedural complications as compared to Watchman LAAC device. On long-term follow-up, both devices showed comparable efficacy and safety.

3.
Int J Cardiol Heart Vasc ; 35: 100847, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34381869

RESUMO

BACKGROUND: Catheter ablation for atrial fibrillation (AF) treatment provides effective and durable pulmonary vein isolation (PVI) and is associated with encouraging clinical outcome. A novel CF sensing temperature-controlled radiofrequency (RF) ablation catheter allows for very high-power short-duration (vHP-SD, 90 W/4 s) ablation aiming a potentially safer, more effective and faster ablation. We thought to evaluate preliminary safety and efficacy of vHP-SD ablation for PVI utilizing a novel vHP-SD catheter. The data was compared to conventional power-controlled ablation index (AI) guided PVI utilizing conventional contact force (CF) sensing catheters. METHODS AND RESULTS: Fifty-six patients with paroxysmal or persistent AF were prospectively enrolled in this study. Twenty-eight consecutive patients underwent vHP-SD based PVI (vHP-SD group) and were compared to 28 consecutive patients treated with conventional CF-sensing catheters utilizing the AI (control group). All PVs were successfully isolated using vHP-SD. The median RF ablation time for vHP-SD was 338 (IQR 286, 367) seconds vs control 1580 (IQR 1350, 1848) seconds (p < 0.0001), the median procedure duration was vHP-SD 55 (IQR 48-60) minutes vs. control 105 (IQR 92-120) minutes (p < 0.0001). No differences in periprocedural complications were observed. CONCLUSIONS: This preliminary data of the novel vHP-SD ablation mode provides safe and effective PVI. Procedure duration and RF ablation time were substantially shorter in the vHP-SD group in comparison to the control group.

4.
J Cardiovasc Electrophysiol ; 32(6): 1553-1560, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33760304

RESUMO

BACKGROUND: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The novel fourth-generation cryoballoon (CB4) incorporates a 40% shorter distal tip. This design change may translate into an increased rate of PVI real-time signal recording, facilitating an individualized ablation strategy using the time to effect (TTE). METHODS AND RESULTS: Three hundred consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled. The first 150 consecutive patients underwent CB2 based PVI (CB2 group) and the last 150 consecutive patients were treated with the CB4 (CB4 group). A total of 594/594 (100%, CB4) and 589/594 (99.2%, CB2) pulmonary veins (PVs) were successfully isolated utilizing the CB4 and CB2, respectively (p = .283). The real-time PVI visualization rate was 47% (CB4) and 39% (CB2; p = .005) and the mean freeze cycle duration 200 ± 90 s (CB4) and 228 ± 110 s (CB2; p < .001), respectively. The total procedure time did not differ between the groups (CB4: 64 ± 32 min) and (CB2: 62 ± 29 min, p = .370). No differences in periprocedural complications were detected. CONCLUSIONS: A higher rate of real-time electrical PV recordings are seen using the CB4 as compared to CB2, which may facilitate an individualized ablation strategy using the TTE.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
5.
Europace ; 19(2): 303-307, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28165525

RESUMO

The purpose of this survey was to assess the current practice in Europe regarding cryoablation for treatment of different cardiac arrhythmias. The data are based on an electronic questionnaire sent to members of the European Heart Rhythm Association Research Network. Responses were received from 49 centres in 18 countries. The results show that cryoablation for supraventricular tachycardia in European centres is an alternative to radiofrequency ablation, which is in accordance with guidelines. There is reasonable consensus regarding clinical results and complications of cryoablation procedure. Some inter-centre variability with respect to patient selection and ablation strategy in cryoablation of atrial fibrillation was demonstrated, underscoring the need for further research.


Assuntos
Arritmias Cardíacas/cirurgia , Criocirurgia/tendências , Padrões de Prática Médica/tendências , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/tendências , Europa (Continente) , Fidelidade a Diretrizes/tendências , Pesquisas sobre Atenção à Saúde , Disparidades em Assistência à Saúde/tendências , Humanos , Guias de Prática Clínica como Assunto , Resultado do Tratamento
7.
J Atr Fibrillation ; 6(1): 861, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-28496858

RESUMO

In the past years, catheter ablation has evolved into an effective treatment option for symptomatic, drug-resistant atrial fibrillation (AF) and it has recently been implemented as a primary treatment strategy for patients with paroxysmal AF. Although a significant number of studies have evaluated the potential benefits of catheter ablation compared with anti-arrhythmic drug (AAD)-therapy, to date, there are only a small number of randomised controlled trials in the literature, and several issues remain unsolved. The aim of this review is to analyze the current literature regarding this important issue and further discuss the question, whether catheter ablation may be more beneficial when compared to AAD therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...